{"id":3412,"date":"2026-11-25T16:40:43","date_gmt":"2026-11-25T16:40:43","guid":{"rendered":"https:\/\/elzhen.com\/blog\/?p=3412"},"modified":"2026-11-25T17:07:57","modified_gmt":"2026-11-25T17:07:57","slug":"different-types-of-ultrasound-artifacts","status":"publish","type":"post","link":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/","title":{"rendered":"10 Types of Ultrasound Artifacts and How to Recognize Them"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">A shadow on an ultrasound image can help identify a gallstone, but it can also hide the tissue behind it. That&#8217;s the tricky part about ultrasound artifacts: they can reveal useful diagnostic information, but they can also make images harder to interpret. Knowing how to recognize them makes all the difference. In this guide, we&#8217;ll look at 10 common ultrasound artifacts, why they occur, and how to reduce their effects.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">What Are Ultrasound Artifacts?<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">In simple terms, an ultrasound artifact is any feature on an image that does not accurately show the patient&#8217;s real anatomy. It may be a structure that appears where nothing exists, a real structure that disappears, or something that appears in the wrong position or with incorrect brightness or shape.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Different types of artifacts occur when sound waves interact with body tissues in ways that differ from the assumptions <\/span><a href=\"https:\/\/elzhen.com\/products\/ultrasounds\"><span style=\"font-weight: 400;\">ultrasound machines<\/span><\/a><span style=\"font-weight: 400;\"> use to create images, such as sound traveling in a straight line at a constant speed and echoes returning from the main beam axis.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Although scanning techniques and machine settings can affect their appearance, most artifacts result from how sound behaves in the body rather than ultrasound machine failure. Some can even be useful, such as acoustic shadowing behind a gallstone, which is explained as follows.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">What Are the Common Types of Ultrasound Artifacts?<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Now that we know what an ultrasound artifact is, let&#8217;s learn about the 10 most common ones.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">These common types of ultrasound artifacts can appear on <\/span><a href=\"https:\/\/elzhen.com\/blog\/a-complete-guide-to-different-types-of-ultrasound-machines\/\"><span style=\"font-weight: 400;\">different types of ultrasound machines<\/span><\/a><span style=\"font-weight: 400;\"> because they come from how sound behaves in tissue, although probe design and machine features can influence their appearance.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">1. Acoustic Shadowing<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Let&#8217;s start with acoustic shadowing, which is a dark band or loss of echoes behind a structure in the patient&#8217;s body. This artifact happens when a structure, such as bone, a stone, or gas, strongly reflects, scatters, or attenuates the sound beam.<\/span><\/p>\n<p>&nbsp;<\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-3416\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/01-acoustic-shadowing-gallstone-ultrasound.webp\" alt=\"Gallbladder ultrasound showing a bright gallstone with a dark acoustic shadow behind it\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/01-acoustic-shadowing-gallstone-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/01-acoustic-shadowing-gallstone-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/01-acoustic-shadowing-gallstone-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/>Why it happens<\/b><span style=\"font-weight: 400;\">: When a sound wave reaches a strong reflector or highly attenuating structure in the body, much of its energy is reflected or absorbed, so very little passes through, and a shadow forms behind the structure.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: A clean shadow is a black band behind a bright edge, while gas often produces a &#8220;dirty&#8221; shadow filled with scattered echoes.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It can be both. Sonographers who use <\/span><a href=\"https:\/\/elzhen.com\/blog\/abdominal-ultrasound-machines-overview\/\"><span style=\"font-weight: 400;\">abdominal ultrasound machines<\/span><\/a><span style=\"font-weight: 400;\"> can recognize gallstones and kidney stones based on these shadows. On the other hand, it can also hide a lesion lying behind bone, calcification, or gas.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Rescan from another angle or acoustic window so the beam passes around the obstruction. Also, use the spatial compounding feature if the ultrasound machine supports it, as it can reduce some shadowing artifacts.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">2. Posterior Acoustic Enhancement<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Another common ultrasound artifact is posterior acoustic enhancement. It is a brighter-than-normal area behind a fluid-filled structure, such as a cyst, the gallbladder, or the urinary bladder.<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3417\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/02-posterior-acoustic-enhancement-renal-cyst-ultrasound.webp\" alt=\"Kidney ultrasound showing a simple renal cyst with a bright band of posterior acoustic enhancement below it\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/02-posterior-acoustic-enhancement-renal-cyst-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/02-posterior-acoustic-enhancement-renal-cyst-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/02-posterior-acoustic-enhancement-renal-cyst-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: Fluid attenuates less sound than the surrounding soft tissue. As a result, more acoustic energy reaches the tissue behind the fluid-filled structure, and the returning echoes appear stronger.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: A bright column of tissue directly below the fluid-filled structure, in contrast with the darker tissue on either side.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It can be helpful because it suggests that a lesion is filled with fluid, not solid, but it is not proof on its own. The extra brightness can also make it harder to assess real changes in the tissue behind it.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Adjust the overall gain or time gain compensation in the deeper zone when necessary to balance the image brightness, or rescan from another view. However, these adjustments change the displayed brightness rather than eliminate the physical enhancement artifact.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">3. Reverberation<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Reverberation is a series of evenly spaced, parallel lines or false echoes seen deeper than a strong reflector. They are created when sound bounces repeatedly between two reflective surfaces.<\/span><\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-3418\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/03-reverberation-artifact-needle-ultrasound.webp\" alt=\"Ultrasound of a needle in the shoulder showing multiple equally spaced reverberation lines beneath the needle\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/03-reverberation-artifact-needle-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/03-reverberation-artifact-needle-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/03-reverberation-artifact-needle-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: Some echo energy is reflected again between the reflector and another surface, such as the probe face. As a result, the machine reads the delayed returns as deeper structures.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: A step-ladder of lines that fade with depth. The first repeated echo can appear at about twice the depth of the real reflector in a typical reverberation pattern.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It is mostly misleading. For example, in echocardiography with <\/span><a href=\"https:\/\/elzhen.com\/cardiac-probes\"><span style=\"font-weight: 400;\">cardiac ultrasound probes<\/span><\/a><span style=\"font-weight: 400;\">, it can mimic a mass, thrombus, or dissection flap near a calcified wall or device lead.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Lower the gain and change the probe angle or window, since reverberation artifacts may disappear or change in appearance in other views.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">4. Comet-Tail and Ring-Down<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">The next common ultrasound artifacts are comet-tail and ring-down. When viewing an ultrasound scan, they appear as bright streaks that extend deep to a small, highly reflective object or a collection of gas bubbles.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3419\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/04-comet-tail-ring-down-artifact-ultrasound.webp\" alt=\"Two ultrasound images comparing short comet- tail artifacts from thyroid colloid with ring-down artifacts from bowel gas\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/04-comet-tail-ring-down-artifact-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/04-comet-tail-ring-down-artifact-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/04-comet-tail-ring-down-artifact-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: Comet-tail comes from rapid reverberations between closely spaced reflectors. Ring-down is associated with the resonance of gas bubbles, which produce a continuous signal that returns to the probe.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: Comet-tail appears as a narrow, tapering bright streak that fades as it goes deeper. Ring-down usually appears as a longer, continuous bright band extending behind the gas bubbles.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It can be both. These artifacts can indicate gas in the bowel or gas within certain abnormal collections, but they do not confirm a gas-forming infection on their own. Comet-tail artifacts can also help identify cholesterol crystals in the gallbladder wall. On the other hand, they can obscure the tissue beneath them.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: You can reposition the transducer to change how the beam meets the object, and reduce the gain if the streak obscures the structures behind it.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">5. Mirror Image<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">A mirror image artifact is a false copy of a structure that is displayed beyond a strong, smooth reflector. This reflector can be the diaphragm, the pleura, or a large vessel wall.<\/span><\/p>\n<p><figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3420 size-full\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/05-mirror-image-artifact-liver-diaphragm-ultrasound.webp\" alt=\"Liver ultrasound showing a mirror image of the liver and a duplicated hepatic vein beyond the diaphragm\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/05-mirror-image-artifact-liver-diaphragm-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/05-mirror-image-artifact-liver-diaphragm-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/05-mirror-image-artifact-liver-diaphragm-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><figcaption>Image: Di Serafino M, et al. Common and \nUncommon Errors in Emergency Ultrasound. \nDiagnostics 2022;12(3):631, CC BY 4.0. Cropped \nand annotated by Elzhen.<\/figcaption><\/figure><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: Part of the sound reflects off the smooth surface, travels toward the structure, and then returns to the probe along a longer path. As a result, the echo takes longer to come back, so the machine places a duplicate of the structure beyond the surface.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: A fainter duplicate appears on the opposite side of the reflector, as if the reflector were a mirror. Doppler flow can also be duplicated.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It is mostly misleading: it can imitate a second vessel or another structure. In <\/span><a href=\"https:\/\/elzhen.com\/blog\/best-veterinary-ultrasound-machines\/\"><span style=\"font-weight: 400;\">veterinary ultrasound examination<\/span><\/a><span style=\"font-weight: 400;\">, a mirrored image of the liver beyond the diaphragm can mimic a structure within the thorax.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Scan from a different angle so the reflector leaves the beam path, since a mirror image may shift or disappear when the probe moves while the real structure stays in its actual position.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">6. Side Lobe and Grating Lobe<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Side-lobe and grating-lobe artifacts are false echoes caused by weaker ultrasound beams traveling outside the main beam. The machine may incorrectly display these echoes as if they came from the main beam.<\/span><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-3421\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/06-side-lobe-artifact-urinary-bladder-ultrasound.webp\" alt=\"Bladder ultrasound with false side lobe echoes in the urine, next to the same bladder appearing clear after the probe is repositioned\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/06-side-lobe-artifact-urinary-bladder-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/06-side-lobe-artifact-urinary-bladder-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/06-side-lobe-artifact-urinary-bladder-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: Besides the main beam, the probe can produce weaker beams to the sides. When these beams hit a strong reflector, the machine draws the echoes as if they came from straight ahead. Grating lobes are additional off-axis beams that can occur in array transducers because of the spacing between their elements.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: It appears as a faint curved or linear band of echoes inside an otherwise echo-free area, resembling sludge, debris, or a thin membrane.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It is misleading because it can imitate debris in the bladder or gallbladder. Additionally, in cardiac imaging, it can mimic a thrombus or an aortic dissection flap.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Move or tilt the probe to see whether the echoes stay, because a side-lobe or grating-lobe echo may shift or disappear while real debris stays in place. Lowering the gain or using harmonic imaging can also reduce some of these artifacts.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">7. Refraction: Edge Shadowing and Double Image<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Refraction artifacts occur when the beam bends at the edge of a curved structure or between tissues with different sound speeds. As a result, thin shadows can appear beside the structure, or a duplicated image may form.<\/span><\/p>\n<p><figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3422 size-full\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/07_refraction_artifact_edge_shadowing_double_image_ultrasound.webp\" alt=\"Two ultrasound images showing refraction: edge shadows beside a round mass, and the aorta displayed twice on color Doppler\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/07_refraction_artifact_edge_shadowing_double_image_ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/07_refraction_artifact_edge_shadowing_double_image_ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/07_refraction_artifact_edge_shadowing_double_image_ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><figcaption>Left: Wu WT, et al. Diagnostics 2020;10(9):645, \nCC BY 4.0. Right: Nevit Dilmen, Wikimedia \nCommons, CC BY-SA 3.0. Annotated by Elzhen.<\/figcaption><\/figure><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: Sound travels at different speeds in different tissues, so a beam crossing a tilted or curved boundary at an oblique angle bends. Therefore, the machine, which assumes a straight path, draws the echoes in the wrong place.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: It can appear as narrow dark lines running down from the sides of a round structure, such as a cyst (edge shadowing).<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It is mostly misleading, since edge shadows can hide a small lesion at the margin of a round structure, and a double image can suggest an extra structure that does not exist.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Change the probe angle or imaging window, or use spatial compounding. This way, the beam meets the boundary from a different direction.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">8. Anisotropy<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Anisotropy is a loss of brightness in fibrous structures such as tendons, ligaments, and nerves.<\/span><\/p>\n<p><figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3423 size-full\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/08-anisotropy-artifact-biceps-tendon-ultrasound.webp\" alt=\"Biceps tendon ultrasound where the tendon looks falsely dark at an oblique angle and normal and bright when the beam is perpendicular\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/08-anisotropy-artifact-biceps-tendon-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/08-anisotropy-artifact-biceps-tendon-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/08-anisotropy-artifact-biceps-tendon-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><figcaption>Image: Wu WT, et al. Diagnostics 2020;10(9):645, \nCC BY 4.0. Cropped and annotated by Elzhen.<\/figcaption><\/figure><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: When the beam does not meet the fibers perpendicularly, the echoes may bounce away from the probe and cause healthy tissue to look dark.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: It looks like a normally bright, fibrillar tendon turns patchy and dark in the part that curves away from the probe.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It is a well-known pitfall in <\/span><a href=\"https:\/\/elzhen.com\/blog\/musculoskeletal-ultrasound-imaging\/\"><span style=\"font-weight: 400;\">musculoskeletal ultrasound scanning<\/span><\/a><span style=\"font-weight: 400;\">, where a healthy tendon can look like tendinosis or a partial tear.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Tilt or rock the probe until the beam is perpendicular to the fibers, and the dark area should brighten, whereas a true tear does not disappear simply by changing the probe angle.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">9. Beam-Width and Slice-Thickness Artifact<\/span><\/h3>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3424 size-full\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/09-beam-width-artifact-focal-zone-ultrasound.webp\" alt=\"Forearm ultrasound where a nerve looks blurred with the focus set too shallow and sharp when the focus is moved to nerve depth\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/09-beam-width-artifact-focal-zone-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/09-beam-width-artifact-focal-zone-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/09-beam-width-artifact-focal-zone-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><\/p>\n<p><span style=\"font-weight: 400;\">Beam-width and slice-thickness artifacts bring echoes from tissue outside the intended scan plane into the image, so echoes seem to come from inside structures that are actually empty.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: The beam is not infinitely thin and has a finite width and thickness. Therefore, the ultrasound machine combines echoes from the full width and thickness of the beam into one flat image.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: It appears as fuzzy echoes inside fluid-filled structures such as the bladder or gallbladder, often forming a curved layer that resembles sludge (&#8220;pseudosludge&#8221;).<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> It is misleading because it can imitate sludge or a mass, and with Doppler it can place flow from a nearby vessel inside a cyst or chamber.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: Set the focal zone at the depth of interest and rescan in a second plane. Using a probe with a narrower beam or better elevational resolution can also help reduce this artifact.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">10. Doppler Artifacts: Aliasing and Blooming<\/span><\/h3>\n<p><figure><img loading=\"lazy\" decoding=\"async\" class=\"alignnone wp-image-3425 size-full\" src=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/10-color-doppler-aliasing-artifact-ultrasound.webp\" alt=\"Color Doppler of a vessel showing aliasing at a low velocity scale and uniform flow color after the scale is raised\" width=\"1920\" height=\"1080\" srcset=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/10-color-doppler-aliasing-artifact-ultrasound.webp 1920w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/10-color-doppler-aliasing-artifact-ultrasound-768x432.webp 768w, https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/10-color-doppler-aliasing-artifact-ultrasound-1536x864.webp 1536w\" sizes=\"(max-width: 1920px) 100vw, 1920px\" \/><figcaption>Image: Di Serafino M, et al. Diagnostics \n2022;12(3):631, CC BY 4.0. Cropped and \nannotated by Elzhen.<\/figcaption><\/figure><\/p>\n<p><span style=\"font-weight: 400;\">Doppler artifacts are false or distorted flow signals in color or spectral Doppler.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The most common are aliasing (high velocities wrapping around the scale) and blooming (color spilling beyond the vessel).<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Why it happens<\/b><span style=\"font-weight: 400;\">: Aliasing happens when the Doppler shift exceeds half the pulse repetition frequency (the Nyquist limit), while blooming results from color gain set too high.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>What it looks like<\/b><span style=\"font-weight: 400;\">: Aliasing shows color wrapping around the scale or spectral peaks cut off and drawn below the baseline. Blooming makes color spill past the vessel wall.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Helpful or misleading?<\/b><span style=\"font-weight: 400;\"> Aliasing can indicate high-velocity flow through a narrowed vessel, but it does not confirm stenosis on its own. Blooming can exaggerate vessel size or make flow appear outside the vessel. Another useful Doppler artifact is twinkling, which can help reveal small stones or calcifications.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>How to fix it<\/b><span style=\"font-weight: 400;\">: For aliasing, raise the velocity scale (pulse repetition frequency) or shift the baseline. For blooming, lower the color gain.<\/span><\/li>\n<\/ul>\n<h2><span style=\"font-weight: 400;\">Artifact or Real Finding? A Quick Checklist<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Sometimes, different types of ultrasound artifacts can look very similar to a real anatomical structure or abnormality. As a sonographer, before making a medical decision based on an unusual finding, you can consider a few practical checks:<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Change the probe angle<\/b><span style=\"font-weight: 400;\">: Reposition or rotate the ultrasound probe to check whether the visuals change or disappear.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Scan in another plane<\/b><span style=\"font-weight: 400;\">: Examine the same area from a different imaging plane to confirm that the structure is present.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Compare adjacent tissues<\/b><span style=\"font-weight: 400;\">: Look at nearby structures to make sure whether the finding follows a consistent anatomical pattern.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Adjust the imaging settings<\/b><span style=\"font-weight: 400;\">: Change gain, depth, focus, or frequency to check whether the appearance is related to image settings.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Use another acoustic window<\/b><span style=\"font-weight: 400;\">: Rescan the same structure from a different window to see whether the finding remains.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Check with Doppler when appropriate<\/b><span style=\"font-weight: 400;\">: Determine whether an apparent flow signal is real, while remembering that Doppler can also produce artifacts.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Look for anatomical continuity<\/b><span style=\"font-weight: 400;\">: Follow the structure through multiple views to check whether it connects to the expected anatomy.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">Paying attention to these factors can help distinguish an ultrasound artifact from a real finding. However, remember that they do not replace clinical judgment or a complete examination.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">How Probe and Ultrasound Choice Affect Ultrasound Artifacts<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">Different types of ultrasound artifacts mainly occur because of how sound waves travel through and interact with body tissues. However, probe design and ultrasound machine features can affect how often these artifacts appear and how clearly they show up in an image.<\/span><\/p>\n<h3><span style=\"font-weight: 400;\">How Probe Choice Affects Artifacts<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">As already explained in our article about <\/span><a href=\"https:\/\/elzhen.com\/blog\/all-types-of-ultrasound-transducers\/\"><span style=\"font-weight: 400;\">different types of ultrasound probes<\/span><\/a><span style=\"font-weight: 400;\">, they have different frequencies, array designs, and beam characteristics, which can influence artifact appearance.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Frequency<\/b><span style=\"font-weight: 400;\">: Higher-frequency probes produce sharper images and better spatial resolution. However, they are not suitable for visualizing deeper structures, especially when attenuation is high.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Linear probes<\/b><span style=\"font-weight: 400;\">: These probes are commonly used for tendons and other superficial structures, where anisotropy is an important consideration. The probe angle must be adjusted carefully to avoid making healthy tendons look abnormal.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Phased array probes<\/b><span style=\"font-weight: 400;\">: These probes are commonly practical for cardiac imaging because their small footprint allows scanning between the ribs. Reverberation and side-lobe artifacts can still affect cardiac images.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Array design<\/b><span style=\"font-weight: 400;\">: The spacing and arrangement of transducer elements influence beam formation and can affect the production of grating lobes.<\/span><\/li>\n<\/ul>\n<h3><span style=\"font-weight: 400;\">Machine Features That Help Reduce Artifacts<\/span><\/h3>\n<p><span style=\"font-weight: 400;\">Modern ultrasound machines include several imaging features that can reduce certain artifacts or improve image quality.<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Tissue harmonic imaging<\/b><span style=\"font-weight: 400;\">: This feature can reduce reverberation, side-lobe artifacts, and other forms of clutter while improving image contrast.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Spatial compounding<\/b><span style=\"font-weight: 400;\">: This feature combines images generated from different beam angles, which can reduce some shadowing and edge-shadowing artifacts.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Speckle reduction<\/b><span style=\"font-weight: 400;\">: This option reduces speckle noise and can make tissue structures easier to visualize. However, excessive processing may remove some fine details.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><b>Focal zone control<\/b><span style=\"font-weight: 400;\">: Adjusting the focal zone to the depth of interest improves lateral resolution in that region, helping structures appear more clearly defined.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Choosing the right ultrasound machine goes beyond comparing image quality or technical configurations. The appropriate system depends on the examination type, clinical applications, transducer requirements, and imaging features needed for daily work.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">At Elzhen, we help hospitals, clinics, and medical professionals choose the right ultrasound machines and transducers based on their clinical needs and budget. Whether you are looking for a refurbished ultrasound machine for general imaging, cardiac examinations, or specialized applications, our team can help you find a suitable solution.<\/span><\/p>\n<h2><span style=\"font-weight: 400;\">Medical References<\/span><\/h2>\n<ul>\n<li><span style=\"font-weight: 400;\">.<\/span><a href=\"https:\/\/www.ovid.com\/jnls\/ultrasound-quarterly\/abstract\/10.1097\/ruq.0b013e3182a80d34~ultrasound-artifacts-classification-applied-physics-with\"><span style=\"font-weight: 400;\">US Artifacts (2009) \u2013 RadioGraphics<\/span><\/a><\/li>\n<li><a href=\"https:\/\/pubs.rsna.org\/doi\/10.1148\/rg.2017160175\"><span style=\"font-weight: 400;\"> Clinical Significance of US Artifacts (2017) \u2013 RadioGraphics<\/span><\/a><\/li>\n<li><a href=\"https:\/\/www.ovid.com\/jnls\/ultrasound-quarterly\/abstract\/10.1097\/ruq.0b013e3182a80d34~ultrasound-artifacts-classification-applied-physics-with\"><span style=\"font-weight: 400;\"> Ultrasound Artifacts: Classification, Applied Physics with Illustrations, and Imaging Appearances (2014)<\/span><\/a><\/li>\n<\/ul>\n","protected":false},"excerpt":{"rendered":"<p>This article explaines 10 common ultrasound artifacts, their causes, and how to recognize them. Learn how probe selection and imaging features can help reduce image distortions and improve image quality.<\/p>\n","protected":false},"author":7,"featured_media":3414,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[50],"tags":[],"class_list":["post-3412","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-ultrasound-tutorial"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v28.8 (Yoast SEO v28.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>10 Common Ultrasound Artifacts: Causes &amp; How to Prevent Them<\/title>\n<meta name=\"description\" content=\"Learn about different ultrasound artifacts, why they occur, how to recognize them, and which techniques can help reduce their impact on image quality.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"10 Types of Ultrasound Artifacts and How to Recognize Them\" \/>\n<meta property=\"og:description\" content=\"Learn about different ultrasound artifacts, why they occur, how to recognize them, and which techniques can help reduce their impact on image quality.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/\" \/>\n<meta property=\"og:site_name\" content=\"Elzhen blog\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/Elzhen2016\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-25T16:40:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-25T17:07:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/ultrasound-artifacts.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1920\" \/>\n\t<meta property=\"og:image:height\" content=\"1080\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Tara Mohseni\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@Elzhen2200\" \/>\n<meta name=\"twitter:site\" content=\"@Elzhen2200\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Tara Mohseni\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"14 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/\"},\"author\":{\"name\":\"Tara Mohseni\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#\\\/schema\\\/person\\\/520f400051a78b60f451be60e80138a9\"},\"headline\":\"10 Types of Ultrasound Artifacts and How to Recognize Them\",\"datePublished\":\"2026-11-25T16:40:43+00:00\",\"dateModified\":\"2026-11-25T17:07:57+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/\"},\"wordCount\":2570,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ultrasound-artifacts.webp\",\"articleSection\":[\"Ultrasound tutorial\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/\",\"url\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/\",\"name\":\"10 Common Ultrasound Artifacts: Causes & How to Prevent Them\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ultrasound-artifacts.webp\",\"datePublished\":\"2026-11-25T16:40:43+00:00\",\"dateModified\":\"2026-11-25T17:07:57+00:00\",\"description\":\"Learn about different ultrasound artifacts, why they occur, how to recognize them, and which techniques can help reduce their impact on image quality.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#primaryimage\",\"url\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ultrasound-artifacts.webp\",\"contentUrl\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ultrasound-artifacts.webp\",\"width\":1920,\"height\":1080},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/different-types-of-ultrasound-artifacts\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Elzhen Blog\",\"item\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"10 Types of Ultrasound Artifacts and How to Recognize Them\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/\",\"name\":\"Overview of ultrasound, probes, and transducers - Elzhen blog\",\"description\":\"Medical Imaging and Ultrasound Machine Technology Insights\",\"publisher\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#organization\"},\"alternateName\":\"Elzhen blog\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#organization\",\"name\":\"Elzhen\",\"url\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/organization-logo.jpg\",\"contentUrl\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/wp-content\\\/uploads\\\/2024\\\/08\\\/organization-logo.jpg\",\"width\":696,\"height\":696,\"caption\":\"Elzhen\"},\"image\":{\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/Elzhen2016\",\"https:\\\/\\\/x.com\\\/Elzhen2200\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/elzhen\",\"https:\\\/\\\/www.instagram.com\\\/elzhen2016\"],\"description\":\"Lenard Healthcare was founded in 2016 in Newmarket, Ontario, Canada by Hodjat Mahmoud, after 15 years of experience developing new technologies for ultrasound repair systems. Today, Lenard Healthcare and its team of highly skilled engineers use their expertise to innovative new ultrasound solutions and repair a variety of ultrasounds and probes from brands such as GE, Philips, SonoSite, Siemens, Esaote, Toshiba, Sonoscape, BK Medical, Aloka, Alpinion, Samsung, Samsung Medison, Hitachi, Supersonic, Konica Minolta and Mindray - at a fraction of what manufacturers charge. They are headquartered in Newmarket and also have an office in Orlando, Florida.\",\"email\":\"elzhen@elzhen.com\",\"telephone\":\"+1 (224) 231-0127\",\"legalName\":\"Lenard Enterprises, Inc.\",\"numberOfEmployees\":{\"@type\":\"QuantitativeValue\",\"minValue\":\"11\",\"maxValue\":\"50\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/#\\\/schema\\\/person\\\/520f400051a78b60f451be60e80138a9\",\"name\":\"Tara Mohseni\",\"description\":\"I found myself in a world where each stroke of the pen is a note, and every page is a symphony!\",\"sameAs\":[\"https:\\\/\\\/ir.linkedin.com\\\/in\\\/tara-mohseni-35231b233\\\/\"],\"url\":\"https:\\\/\\\/elzhen.com\\\/blog\\\/author\\\/t-mohseni\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"10 Common Ultrasound Artifacts: Causes & How to Prevent Them","description":"Learn about different ultrasound artifacts, why they occur, how to recognize them, and which techniques can help reduce their impact on image quality.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/","og_locale":"en_US","og_type":"article","og_title":"10 Types of Ultrasound Artifacts and How to Recognize Them","og_description":"Learn about different ultrasound artifacts, why they occur, how to recognize them, and which techniques can help reduce their impact on image quality.","og_url":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/","og_site_name":"Elzhen blog","article_publisher":"https:\/\/www.facebook.com\/Elzhen2016","article_published_time":"2026-11-25T16:40:43+00:00","article_modified_time":"2026-11-25T17:07:57+00:00","og_image":[{"width":1920,"height":1080,"url":"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/ultrasound-artifacts.webp","type":"image\/webp"}],"author":"Tara Mohseni","twitter_card":"summary_large_image","twitter_creator":"@Elzhen2200","twitter_site":"@Elzhen2200","twitter_misc":{"Written by":"Tara Mohseni","Est. reading time":"14 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#article","isPartOf":{"@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/"},"author":{"name":"Tara Mohseni","@id":"https:\/\/elzhen.com\/blog\/#\/schema\/person\/520f400051a78b60f451be60e80138a9"},"headline":"10 Types of Ultrasound Artifacts and How to Recognize Them","datePublished":"2026-11-25T16:40:43+00:00","dateModified":"2026-11-25T17:07:57+00:00","mainEntityOfPage":{"@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/"},"wordCount":2570,"commentCount":0,"publisher":{"@id":"https:\/\/elzhen.com\/blog\/#organization"},"image":{"@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#primaryimage"},"thumbnailUrl":"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/ultrasound-artifacts.webp","articleSection":["Ultrasound tutorial"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/","url":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/","name":"10 Common Ultrasound Artifacts: Causes & How to Prevent Them","isPartOf":{"@id":"https:\/\/elzhen.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#primaryimage"},"image":{"@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#primaryimage"},"thumbnailUrl":"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/ultrasound-artifacts.webp","datePublished":"2026-11-25T16:40:43+00:00","dateModified":"2026-11-25T17:07:57+00:00","description":"Learn about different ultrasound artifacts, why they occur, how to recognize them, and which techniques can help reduce their impact on image quality.","breadcrumb":{"@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#primaryimage","url":"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/ultrasound-artifacts.webp","contentUrl":"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2026\/11\/ultrasound-artifacts.webp","width":1920,"height":1080},{"@type":"BreadcrumbList","@id":"https:\/\/elzhen.com\/blog\/different-types-of-ultrasound-artifacts\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Elzhen Blog","item":"https:\/\/elzhen.com\/blog\/"},{"@type":"ListItem","position":2,"name":"10 Types of Ultrasound Artifacts and How to Recognize Them"}]},{"@type":"WebSite","@id":"https:\/\/elzhen.com\/blog\/#website","url":"https:\/\/elzhen.com\/blog\/","name":"Overview of ultrasound, probes, and transducers - Elzhen blog","description":"Medical Imaging and Ultrasound Machine Technology Insights","publisher":{"@id":"https:\/\/elzhen.com\/blog\/#organization"},"alternateName":"Elzhen blog","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/elzhen.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/elzhen.com\/blog\/#organization","name":"Elzhen","url":"https:\/\/elzhen.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/elzhen.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2024\/08\/organization-logo.jpg","contentUrl":"https:\/\/elzhen.com\/blog\/wp-content\/uploads\/2024\/08\/organization-logo.jpg","width":696,"height":696,"caption":"Elzhen"},"image":{"@id":"https:\/\/elzhen.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/Elzhen2016","https:\/\/x.com\/Elzhen2200","https:\/\/www.linkedin.com\/company\/elzhen","https:\/\/www.instagram.com\/elzhen2016"],"description":"Lenard Healthcare was founded in 2016 in Newmarket, Ontario, Canada by Hodjat Mahmoud, after 15 years of experience developing new technologies for ultrasound repair systems. Today, Lenard Healthcare and its team of highly skilled engineers use their expertise to innovative new ultrasound solutions and repair a variety of ultrasounds and probes from brands such as GE, Philips, SonoSite, Siemens, Esaote, Toshiba, Sonoscape, BK Medical, Aloka, Alpinion, Samsung, Samsung Medison, Hitachi, Supersonic, Konica Minolta and Mindray - at a fraction of what manufacturers charge. They are headquartered in Newmarket and also have an office in Orlando, Florida.","email":"elzhen@elzhen.com","telephone":"+1 (224) 231-0127","legalName":"Lenard Enterprises, Inc.","numberOfEmployees":{"@type":"QuantitativeValue","minValue":"11","maxValue":"50"}},{"@type":"Person","@id":"https:\/\/elzhen.com\/blog\/#\/schema\/person\/520f400051a78b60f451be60e80138a9","name":"Tara Mohseni","description":"I found myself in a world where each stroke of the pen is a note, and every page is a symphony!","sameAs":["https:\/\/ir.linkedin.com\/in\/tara-mohseni-35231b233\/"],"url":"https:\/\/elzhen.com\/blog\/author\/t-mohseni\/"}]}},"_links":{"self":[{"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/posts\/3412","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/comments?post=3412"}],"version-history":[{"count":6,"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/posts\/3412\/revisions"}],"predecessor-version":[{"id":3429,"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/posts\/3412\/revisions\/3429"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/media\/3414"}],"wp:attachment":[{"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/media?parent=3412"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/categories?post=3412"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/elzhen.com\/blog\/wp-json\/wp\/v2\/tags?post=3412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}